Horizontal Single-Stage Pump
The horizontal single-stage pump adopts a hydraulically optimized design, with…

Intellicold Butterfly Valve
The nominal diameter covers DN50 to DN2000, and the nominal…

Intellicold Safety Valve
Nominal pressure: PN1.0-PN42.0MPa, nominal diameter: DN15-DN300, set pressure range: 0.02-40MPa,…

Intellicold Float valve
The nominal diameter covers DN15-DN300, and the working pressure reaches…

Intellicold Gate Valve
The nominal diameter covers DN15 to DN1200, and the nominal…

Intellicold Check Valve
The nominal diameter covers DN15-DN1200, and the nominal pressure reaches…
Recent News
Horizontal Single-Stage Pump
The horizontal single-stage pump adopts a hydraulically optimized design, with a motor efficiency of over 92% and energy consumption 15%-20% lower than traditional pumps. It covers flow rates of 8-160m³/h and head of 10-80m with DN50-DN125 diameter. It has a compact structure (shortest length 450mm) and shaft seal life of over 8000 hours, making it suitable for efficient transportation in various scenarios such as municipal, chemical, and HVAC industries.
Intellicold Butterfly Valve
The nominal diameter covers DN50 to DN2000, and the nominal pressure reaches PN1.0 to PN4.0MPa. Cast iron, cast steel and stainless steel materials are available. It is suitable for the temperature range of -20 ℃ to 400℃ and various media such as water, oil and gas.
Intellicold Safety Valve
Nominal pressure: PN1.0-PN42.0MPa, nominal diameter: DN15-DN300, set pressure range: 0.02-40MPa, supports wide temperature range from -196 ℃ to 600℃, made of cast steel/stainless steel/Hastelloy. The seal complies with API 527 standard (leakage ≤0.1 bubbles per minute), and the reseating pressure deviation is ≤10%.
Intellicold Float valve
The nominal diameter covers DN15-DN300, and the working pressure reaches PN0.6-PN2.5MPa. Cast iron, stainless steel and brass materials are available. It is suitable for various media such as water, oil, weak acid and weak alkali. Its water level control accuracy is ±5mm, the opening and closing response time is ≤1 second, the sealing leakage is ≤0.01L/h, and the temperature resistance range is -10 ℃ to 120℃.
Intellicold Gate Valve
The nominal diameter covers DN15 to DN1200, and the nominal pressure reaches PN1.0 to PN16.0MPa. Cast iron, cast steel and stainless steel materials are available. It is suitable for the temperature range of -29 ℃ to 425℃ and various media such as water, oil and steam. It adopts a hard seal/soft seal structure, with a leakage rate of ≤0.01%× rated flow. It can be opened and closed over 10,000 times, has a low operating torque, and is compatible with manual/electric/pneumatic actuators.
Intellicold Check Valve
The nominal diameter covers DN15-DN1200, and the nominal pressure reaches PN1.0-PN42.0MPa. Cast iron, cast steel and stainless steel materials are available. The temperature resistance range is -196 ℃-550℃. It is suitable for water, oil, steam and weakly corrosive fluids. Its sealing complies with API 598 standard, with leakage ≤0.01% of the rated flow and opening and closing response ≤0.5 seconds (waterproof hammer).
Vertical Single-Stage Pump
Vertical single-stage pumps occupy only 40% of the space of horizontal pumps (minimum height 650mm), with motor efficiency ≥91% and energy consumption reduced by 12%-18%. They cover flow rates of 5-200m³/h and head of 10-100m with DN40-DN150 diameters, and have a shaft seal life of over 7500 hours. They are suitable for efficient transportation in space-constrained scenarios such as water supply, chemical industry, and HVAC.
Fan Coil Unit (Ceiling-Mounted/Concealed) (FCU)
The cooling capacity covers 2.5-17kW, the heating capacity 3.0-19kW, and the air volume 280-2000m³/h. It supports three static pressure levels: low (≤12Pa), medium (12-30Pa), and high (30-50Pa). The operating noise is only 28-42dB (A), making it suitable for different ceiling depths and noise reduction requirements. Its energy efficiency ratio (COP) is ≥3.2 (meeting the national first-class energy efficiency standard), and it is applicable to cold water temperatures of 7-12℃ and hot water temperatures of 40-55℃.
Air-Cooled Modular Unit(ACMU)
The single module has a cooling capacity of 25-130kW and a heating capacity of 28-145kW. It supports parallel connection of modules, with a cooling COP of ≥3.2 and an IPLV of ≥4.0 (first-class energy efficiency). It is suitable for wide-temperature operating conditions ranging from -25 ℃ to 48℃, and has a low low-temperature heating attenuation rate (COP≥2.0 at -10℃). It adopts R32/R410A environmentally friendly refrigerant, with operating noise ≤65dB (A), water-side resistance ≤8kPa, and supports intelligent frequency conversion.
Air Handling Unit(AHU)
The air processing volume covers 1000-100,000 m³/h, with cooling capacity ranging from 10 to 800kW and heating capacity from 12 to 900kW. The filtration efficiency can be selected from G4 (primary), F8 (medium) to H13 (high efficiency). The temperature and humidity control accuracy reaches ±0.5℃ for temperature and ±3% for humidity. Its operating noise is ≤55dB (A), and the heat recovery efficiency is ≥75% (a heat recovery module is optional). The fan adopts a variable frequency motor (energy efficiency grade IE3), and supports modular assembly and customized functions (such as humidification and purification).